This controller is Single shafts sunshine tracing controller, it adopt the high precision internal andexternal ring hole type sensor to detect the sunshine direction, process analyse judgement through theSCM electric circuit on the controller to the sensor signal, execute the whole process of tracing sunshinethrough the corresponding motor of electric relay assembly control platform on the electric circuit board,at the same time, it still has the functions such as leveling when meet wind (need optionally configure theair speed sensor), reset in cloudy day or night, adopt the English liquid crystal display to indicate thecorresponding parameters, and able to use the keys on the controller or keys of infrared controller (needoptionally configure the remoter) to set various parameters.
This controller corresponding platform required to be Single freedom platform, the drive motor ofplatform is DC brush motor, the motor voltage is 12V or 24V, current of single motor must be less than15A (default that each one shaft configure 10A fuse). Four direction of platform all should have limitwitch.
DC IN:10-28V DC OUT=DC IN IMAX<15A
The controller formed with the below main components:
1. Main controller +sunshine sensor:
Mounting holes of main controller 4MM: left and right hole distance: 174MM, up and down hole distance:6oMN
The product adopt the water proof box as the external shell, it has raining proof performance when vertically mounted, the max has 6 pieces water proof wire outlet port and used in circuit connection, all circuits connection on the main board adopt terminal wiring method, the up cover has screen indication and six operating keys, able to observe the parameters and process manually operating or parameter setting.
2. Sunshine sensor:
The unique deep hole type internal and external Single inspection method generate differentsunshine radiation voltage value at four directions through shielded by the middle pheasant shape cap,transmit to main board through 5 cores cable with 3m length. The mounting method is 2 pieces M6 boltswhich distant 40MM fix and configure the transparent cover, it has a certain dust proof and water prooffunction.
3.Windspeed sensor: (Optionally configured parts)
Wind speed sensor used to test the environment Wind speed, the controller control platform drive to theposition where able to avoid wind to protect the platform when Wind speed achieved the protection valuewhich set by the controller, the default air speed sensor configured the wire length is 3m. (If the customerself configured the Wind speed sensor then need select and use the voltage signal type Wind speed sensor)4.Infrared remoter (optional part)
The detail instruction:
Each function of control board as below:
1.Display screen2. Remote receive head3.Operating button4.Output indicate lamp of east and south shafts5. Buzer6.Output indicate lamp of south and north shafts7. Euse of of south and north
shatts8. Fuse of south and north shafts9. Sunshine sensor joggle (from left to right are ground, east,
west, south, north and front)10. Wind speed sensor joggle (from left to hundred are supply power V+,
GND, signal input)11. Motor joggle of east and west shafts12. Power supply input (12 or 24V DC,
left positive and right negative)13Motor josele of south and north shafts
14. limit terminal joggle (from left to right are ground, ground, east, west, south, north, front and front)
Mounting methods:
Sunshine sensor mounting:
Mount the sunshine sensor on the platform and plane action along with the platform attention it
need parallel to the up plane of platform, the wire outlet hole direction on the test head need be face to
eround when plattiorm vertical.
The test head should do best to mount at north eastedge of platform when at the northern
hemisphere. It should be south east edge when at the southern hemisphere.
CC2
The sun sensor is
6MM*2mounted on the40MMC
North East edge
EAST
Location map of mounting hole of sunlight
detection head
Main control box mounting:
The main control box should be mounted nearby the base pile of platform, needn't action along with
the platform, do best to make ensure it will not be raining, sunshine and other affection, the wire outlet
hole downward to prevent the rain water flow in. The best is able to observe and operate conveniently.
Fix hole position diagram of controller
AMM
-174MM-
60MM
Wind speed sensormounting:
The Wind speed sensor should be mounted nearby the platform, where able to validly blowing by the
air force. Don't close to wall corner or ground, the better is one pile support mounting.
Lead the wire of Wind speed sensor into control box and connect well according to the marks,
remain margin and firmly mounted.
Attention that standard contoured Wind speed sensor wiring method are: black with white stripes
connect the signal input IN, black connect G, V+ supply power needn't connection.
If outsourced the other factory Wind speed sensor then discriminate the V+, negative, signal, connect
in according to specification marks then okay.
The Wind speed sensor terminal V+ on this control board is power supply voltage value (12-24V).
Required the signal output must be voltage type and the signal range less than 5V
Note: